Laboratory
Clinical chemistry | REAGENTS


Ref. Product Quantity Method Docum.
met    sds

17617
Acid Phosphatase 120 mL (6x20)
(TOTAL AND PROSTATIC) - Kinetic colorimetric method - Wavelenght 405 nm - Stable 7 days at 2-8 °C from the preparation date - Temp. 37 °C - Citrate buffer - Substrate chromogen: alpha-naphtylphosphate-Fast Red TR salt - Ratio: Sample/Reagent: 1/10 - Kinetic reading - Lag phase 4 min - Reading time 2 min - Linearity 75 U/L.
6x20 mL
Colorimetric
    


17600H
Albumin Liquid 390 mL (6x65)
Bromocresol green method - Wavelength 600 nm - SINGLE LIQUID REAGENT - Ratio: Sample/Reagent 1/120 - Immediate reading; color stable 1 hour - Linearity 7 g/dL.
6x65 mL
Colorimetric
    


17003
Aldolase 102.5 mL (5x20+2x1+1x0.5)
Enzymatic UV method with TPI-GDH - Wavelength 340 nm - THREE REAGENTS with min stability of 14 days from the preparation date - Ratio: Sample/Reagent 1/Reagent 2/Reagent 3: 1/12.5/0.25/0.05 - Kinetic reading with reaction time 25 min - Linearity 30 U/L - Sensitivity 1 U/L.
5x20+2x1+1x0.5 mL
Colorimetric
    


17308H
ALP Liquid 100 mL (4x20+1x20)
DGKC optimized kinetic method - Wavelength 415 nm - Temperature 37 °C - DEA buffer and starter PNPP Liquid - Kinetic reading - TWO LIQUID REAGENTS - Ratio: Sample/Reagent 1/Reagent 2: 1/50/12.5 - Lag phase 1 min - Reading time 3 min - Linearity 700 U/L.
4x20; 1x20 mL
Colorimetric
    


17238A
ALT Color Microwell (192 tests)
Enzymatic colorimetric test on microwell to be used for the determination of ALT with two reading points and calculation against calibrator - POX/POD/ESHPT method - Fixed-time Wavelength 550 nm - Ratio: Sample/Reagent A/Solution BC: 1/10/10 - Reaction time 30 min - Linearity 250 U/L - Lyophilized Calibrator (2x0.5 mL) included in the kit.
Colorimetric
    

16226
Pyridoxalphosphate (P5P) for 2000 mL (40x50)
Auxiliary reagent for ALT/AST method IFCC; each tablet must be dissolved in 50 mL of Reagent 1- Ready for use with REF 17234H and REF 17224H.
40 pcs
Colorimetric
    

17224H
AST UV Liquid 149 mL (2x65+1x19)
IFCC optimized UV method - Wavelength 340 nm - TWO LIQUID REAGENTS with substrate starter - Ratio: Sample/Reagent 1/Reagent 2: 1/10/1 - Kinetic reading - Lag phase 1 min - Reading time 3 min - Linearity 200 U/L. Upon request: auxiliary reagent Pyridoxalphosphate (P5P) 40 tablets REF 16226, to conform with IFCC recommendations. Each tablet must be dissolved in 50 mL of Reagent 1.
2x65; 1x19 mL
Colorimetric
    

17234H
ALT UV Liquid 149 mL (2x65+1x19)
IFCC optimized UV method - Wavelength 340 nm - TWO LIQUID REAGENTS with substrate starter - Ratio: Sample/Reagent1/Reagent 2: 1/11/1.5 - Kinetic reading - Lag phase 1 min - Reading time 3 min - Linearity 300 U/L. Upon request: auxiliary reagent Pyridoxalphosphate (P5P) 40 tablets REF 16226, to conform with IFCC recommendations. Each tablet must be dissolved in 50 mL of Reagent 1.
2x65; 1x19 mL
Colorimetric
    


17660
Ammonia Ultra 60 mL (3x20)
Enzymatic UV method (GLDH) - SINGLE LIQUID REAGENT - Wavelength 340 nm - Ratio: Sample/Reagent: 1/11 - Linearity 1700 µg/dL - Standard included in the kit - Three levels Ammonia Controls (REF 16635) are available separately.
3x20 mL
Colorimetric
    


17631H
Pancreatic Amylase 83 mL (1x65+1x18)
Blocked pNPG7 (EPS) kinetic method according to IFCC recommendations - Inhibition of salivary amylase with double monoclonal antibodies- Wavelength 415 nm - TWO LIQUID REAGENTS - Ratio: Sample/Reagent 1/Reagent 2: 1/25/6.25 - the same R2 as in the alpha Amylase Liquid kit is used - Kinetic reading - Reaction time 8 min - Linearity 2000 U/L.
1x65; 1x18 mL
Colorimetric
    

17632H
Amylase Liquid 83 mL (1x65+1x18)
Protected pNPG7 (EPS) colorimetric method according to IFCC recommendations - Wavelength 415 nm - TWO LIQUID REAGENTS - Ratio: Sample/Reagent 1/Reagent 2: 1/25/6.25 - Kinetic reading - Lag phase 1 min - Reading time 3 min - Linearity 1500 U/L.
1x65; 1x18 mL
Colorimetric
    


17002B
Bile Acids TBA 63 mL (5x10+1x13)
Enzymatic colorimetric method with NBT - Wavelength 546 nm - Minimum stability of reagents 7 days after preparation - TWO REAGENTS (fixed time reaction in 5 min) - Ratio: Sample/Solution R1/Reagent 2: 1/2/0.5 - Linearity 200 µmol/L - Standard included, Bile Acids Controls (REF 16002A) available separately.
5x10; 1x13 mL
Colorimetric
    


17643H
Bilirubin Direct Liquid 195 mL (4x45+1x15)
Colorimetric Jendrassik and Grof method - Wavelength 570 nm - Two analytical procedures: TWO REAGENTS with sample blank, n. tests (60-180) - Ratio: Sample/Reagent 1/Reagent 2: 1/15/0.5 and single reagent without sample blank n. tests (120-360) - Ratio: Sample/Reagent: 1/15 - Reaction time 2 min - Linearity 20 mg/dL.
4x45; 1x15 mL
Colorimetric
    


17642H
Bilirubin Total Liquid 335 mL (7x45+1x20)
Colorimetric Jendrassik and Grof method - Wavelength 570 nm - Two analytical procedures: TWO REAGENTS with sample blank, n. tests (120-180) - Ratio: Sample/Reagent 1/Reagent 2: 1/15/0.5 and single reagent without sample blank, n. tests (240-360) Ratio: Sample/Reagent 1/15 - Reaction time 5 min - Linearity 20 mg/dL.
7x45; 1x20 mL
Colorimetric
    


17667H
Calcium Liquid 215 mL (3x55+1x50)
Direct colorimetric method CPC (Cresolphtalein complexone) - Wavelength 600 nm - TWO REAGENTS LIQUID READY TO USE - Ratio: Sample/Reagent 1/Reagent 2: 1/25/10 - Reaction time 10 min at 37 °C - Linearity 20 mg/dL.
3x55; 1x50 mL
Colorimetric
    


17644H
Cholesterol Liquid 390 mL (6x65)
Enzymatic colorimetric Trinder method - Wavelength 505 nm - SINGLE LIQUID REAGENT - Ratio: Sample/Reagent: 1/100 - End-Point reaction 5 min - Color stable 60 min - Linearity 700 mg/dL.
6x65 mL
Colorimetric
    


17201H
Cholesterol HDL Liquid NG 85 mL (1x65+1x20)
Direct method (“elimination technique”) in homogeneous phase - Without precipitation (US Patent N° 6,479,249 B2) - Wavelength 600 nm - TWO LIQUID REAGENTS - READY TO USE - Improved performances - Ratio: Sample/Reagent 1/Regent 2: 1/75/25 - Reaction time 8 min - Linearity 150 mg/dL - Calibrator (REF 1120201and REF 16550) and Controls (REF 34Q021, REF 16150 and REF 16250) available separately.
1x65; 1x20 mL
Colorimetric
    


17203H
Cholesterol LDL Liquid NG 85 mL (1x65+1x20)
Direct method ("elimination technique") in homogeneous phase without precipitation (US Patent N° 6,194,164,B1) - Wavelength 600 nm - TWO LIQUID REAGENTS - READY TO USE - Improved performances - Ratio: Sample/Reagent 1/Reagent 2: 1/75/25 - Reaction time 10 min - Linearity 1000 mg/dL - Calibrator (REF 1120201 or REF 16550) and Controls (REF 34Q021, REF 16150 and REF 16250) available separately.
1x65; 1x20 mL
Colorimetric
    


17019H
Cholinesterase Liquid 120 mL (2x50+1x20)
Kinetic-colorimetric optimized method according to DGKC recommendations - Substrate Butyryltiocholine - TWO LIQUID REAGENTS - Wavelength 415 nm - Ratio: Sample/Reagent 1/Reagent 2: 1/50/10 - Kinetic reading - Lag phase 90 sec - Reading time 90 sec - Linearity 22.000 U/L.- FDA 510 (K) number: K981800.
2x50; 1x20 mL
Colorimetric
    


17296H
CK-NAC Liquid 83 mL (1x65+1x18)
Kinetic method according to IFCC recommendations - Wavelength 340 nm - Temperature 37 °C - TWO LIQUID REAGENTS with substrate starter - Ratio: Sample/Reagent 1/Reagent 2: 1/20/5 at 37 °C - Kinetic reading - Lag phase 2 min - Reading time 3 min - Linearity 1000 U/L.
1x65; 1x18 mL
Colorimetric
    


17649H
CK-MB Liquid 80 mL (1x65+1x15)
Immunological test method for the determination of CK-MB sub-units by inhibitor antibodies - Wavelength 340 nm - Tempeature 37 °C – TWO LIQUID REAGENTS - Ratio: Sample/Reagent 1/Reagent 2: 1/20.8/4.2 - Measuring range up to 1000 U/L – Calibrator (REF 16299C) and Control (REF 16299S) available separately.
1x65; 1x15 mL
Colorimetric
    


17638H
Copper 121 mL (5x20+1x21)
Direct colorimetric DiBr-PAESA method - Wavelength 570 nm - Without deproteinization on serum and plasma - TWO REAGENTS stable 45 days at 2-8 °C after preparation - End-Point reaction in 5 min at 37 °C - color stable 60 min - Ratio: Sample/Reagent 1/Reagent 2: 1/20/4 - Linearity 500 µg/dL - Standard included in the kit.
5x20; 1x21 mL
Colorimetric
    

17106
Copper 53 mL (5x10+1x3)
5x10; 1x3 mL
Colorimetric
    

17109
Copper Urine 12 mL (4x3)
Direct colorimetric method DiBr-PAESA - Wavelength 582 nm - Without deproteinization on urine - Ratio: Sample/Reagent 1/Reagent 2: 10/1/1 - End-Point reaction in 5 min at room temperature - Linearity 20 µg/dL - Standard included in the kit.
4x3 mL
Colorimetric
    


17654H
Creatinine Enz Liquid 136 mL (2x50 + 2x18 mL)
Enzymatic colorimetric Trinder method (SOX-POD-ESPMT) without deproteinization with starter reagent - Wavelength 546 nm - Fixed time reaction: reaction time 5 min after starter with blank sample subtraction - Ratio: Sample/Reagent 1/Reagent 2: 1/45/15 - Linearity 50 mg/dL.
2x50; 2x18 mL
Colorimetric
    

17609H
Creatinine Liquid 390 mL (3x65+3x65)
Kinetic method with alkaline picrate (Jaffe' mod.) - Wavelength 505 nm - Without deproteinization - TWO LIQUID REAGENTS - Ratio: Sample/Reagent 1/Reagent 2: 1/6.25/6.25 - Fixed time reaction - Lag phase 60 sec - Reading time 1 min - Linearity 15 mg/dL.
3x65; 3x65 mL
Colorimetric
    


17018
Dibucaine CHE Liquid for 300 mL (6x50)
Auxiliary reagent for the determination of the dibucaine number (DN); to be used with Cholinesterase Liquid REF 17019H - Stable 30 days at 2-8 °C - Reaction time 3 min.
6x50 mL
Colorimetric
    


17350H
Fructosamine 54 mL (3x18)
Colorimetric method with NBT - SINGLE REAGENT stable 14 days after reconstitution - Ratio: Sample/Reagent: 1/19.2 - Wavelength 546 nm - Fixed Time reaction from 9 to 10 min - Calibrator is included in the kit, Controls (REF 16352 and REF 16353) available separately.
3x18 mL
Colorimetric
    


17336H
Gamma GT Liquid 83 mL (1x65+1x18)
Kinetic colorimetric according to Szaz mod/IFCC mod. method. - Buffer and substrate liquid Carboxy-Glupa - Wavelength 415 nm - Temperature 37 °C - TWO LIQUID REAGENTS - Ratio: Sample/Reagent 1/Reagent 2: 1/10/2.5 - Kinetic reading - Lag phase 30-60 sec - Reading time 3 min - Linearity 700 U/L.
1x65; 1x18 mL
Colorimetric
    


17630H
Glucose Liquid 390 mL (6x65)
Enzymatic colorimetric Trinder method - Wavelength 505 nm - SINGLE LIQUID REAGENT - Ratio: Sample/Reagent: 1/100 - End-Point reaction 10 min - Color stable 60 min - Linearity 400 mg/dL.
6x65 mL
Colorimetric
    


17005
G6P-DH 124 mL (1x100+1x2+1x2+1x20)
Enzymatic UV method with NADP on erythrocytes - Wavelength 340 nm - THREE REAGENTS, stable at least 4 weeks after preparation - Kinetic reading - Lag phase 0 sec - Reading 3 min - Total reaction time 8 min (erythrocytes). Recommended controls: (REF G5888 Control Deficit, REF G5029 Control Intermediate and REF G6888 Control Normal) – Available through Trinity Biotech - Ireland.
100 mL
Colorimetric
    


17636
HBDH Liquid 112 mL (2x50+1x12)
a-hydroxybutirate deydrogenase DGKC optimized UV method - TWO LIQUID REAGENTS - Wavelength 340 nm - Temp. 30-37 °C - Ratio: Sample/Reagent 1/Reagent 2: 1/30/3 - Kinetic reading - Lag phase 60 sec - Reading time 3 min - Linearity 500 U/L at 37 °C.
2x50; 1x12 mL
Colorimetric
    


1741501
HbA1c Direct Latex 40 mL (1x30 + 1x10)
Hemoglobin Direct immuno-turbidimetric latex determination - Wavelength 600 nm - TWO LIQUID REAGENTS - 50 days stability after Reagent opening - Ratio: Sample/Reagent 1/Reagent 2: 1/37.5/12.5 - Linearity: 1.0%-16% HbA1c - Calibrator (REF 1741801), Control (REF 1741901) and Diluent* for hemolysate preparation (REF 1741601) available separately. *: Hemolysis Reagent HbA1c (2 x70 mL)
1x30; 1x10 mL
Colorimetric
    

17416
Hemolysis Reagent HbA1c 270 mL (3x90)
Auxiliary reagent to be used with the kit Hemoglobin A1c Direct Latex (REF 17415A) for samples hemolysis.
3x90 mL
Colorimetric
    

1741601
Hemolysis Reagent HbA1c 140 mL (2x70)
Auxiliary reagent to be used with the kit HbA1c Direct Latex (REF 1741501) for samples hemolysis.
2x70 mL mL
Colorimetric
    

17415A

1x30; 1x9.5; 1x0.5 mL
    


17370H
Homocysteine Liquid 35 mL (1x30+1x5)
Enzymatic Homocysteine assay in serum and heparinised plasma using a new Liquid Stable (LS) 2-part homocysteine reagent for quantitative determination - The concentration of HCY in the sample is directly proportional to the conversion rate of NADH at 340 nm – TWO REAGENTS – Ratio: Sample/Reagent 1/Reagent 2: 1/15.1/1.5 – Linearity 1-46 µmol/L – Sensitivity 1 µmol/L - Calibrator included in the kit – Controls (REF 16370S) available separately.
1x30; 1x5 mL
Colorimetric
    


17648H
Iron Liquid 210 mL (3x65+1x15)
Direct colorimetric Ferene method without deproteinization on serum and plasma - Ratio: Sample/Reagent 1/Reagent 2: 1/12.5/1 - TWO LIQUID REAGENTS - Wavelength 600 - Linearity 1000 µg/dL - End-Point reaction in 5 min at 37 °C - Sample blank required - Volumes R1 and R2 are balanced for automated analyzers.
3x65; 1x15 mL
Colorimetric
    


17639
UIBC Liquid 91 mL (2x40+1x11)
Unsaturated Iron Binding Capacity - Determination with direct Ferene method in homogeneous phase with liquid reagents - Wavelength 593 nm - TWO REAGENTS - Reagents stable 60 days at 2-8 °C - Ratio: Sample/Reagent 1/Reagent 2: 1/10/1 - Standard included in the kit - Reaction time 10 min.
2x40; 1x11 mL
Colorimetric
    


17285
Lactate Dry-Fast 50 mL (5x10)
Enzymatic colorimetric Trinder method - Plasma or liquor - Without sample blank - Wavelength 540 nm - SINGLE REAGENT stable 30 days at 2-8 °C after reconstitution - Ratio: Sample/Reagent: 1/100 - End-Point reaction 5 min - Color stable 60 min - Linearity 210 mg/dL.
5x10 mL
Colorimetric
    


17294H
LDH Liquid 215 mL (3x65+1x19)
Optimized SFBC UV method (pyruvate-lactate) - Wavelength 340 nm - TWO LIQUID REAGENTS with substrate starter - Ratio: Sample/Reagent 1/Reagent 2: 1/50/5 - Kinetic reading - Lag phase 60 sec - Reading time 3 min - Linearity 1200 U/L - Volumes R1 and R2 are balanced for automated analyzer. Note - Recommended calibrator: REF 16550 Clin Chem Cal (Mod. DGKC).
3x65; 1x20 mL
Colorimetric
    


17616H
Lipase Color Liquid 242 mL (4x50 + 2x21)
Colorimetric direct method with long chain substrate (dilauryl-glyceroglutaric-methylresorufineester) specific for lipase - Liquid emulsion - TWO LIQUID REAGENTS - Temperature 37 °C - Wavelength 570 nm - Ratio: Sample/Reagent 1/Reagent 2: 1/100/20 - Kinetic reading - Lag phase 1 min - Reading 2 min - Linearity 250 U/L (methylresorufine units) - FDA 510 (K) number: K961179.
4x50; 2x21 mL
Colorimetric
    

17401B
Lipase Color Liquid 48 mL (4x10 + 1x8)
Colorimetric direct method with long chain substrate (dilauryl-glyceroglutaric-methylresorufineester) specific for lipase - Liquid emulsion - TWO LIQUID REAGENTS - Temperature 37 °C - Wavelength 580 nm - Ratio: Sample/Reagent 1/Reagent 2: 1/100/20 - Kinetic reading - Lag phase 1 min - Reading 2 min - Linearity 250 U/L (methylresorufine units) - Calibrator included in the kit - FDA 510 (K) number: K961179.
4x10; 1x8 mL
Colorimetric
    


17637H
Magnesium Liquid 120 mL (6x20)
Direct colorimetric method Xilidil Blue-1 - Wavelength 505 nm - LIQUID SINGLE REAGENT - Without sample blank - Ratio: Sample/Reagent: 1/100 - Immediate reading - Color stable 30 min - Linearity 10 mg/dL.
6x20 mL
Colorimetric
    


17320
Phospholipids 50 mL (5x10)
Enzymatic colorimetric Trinder method - Wavelength 520 nm - SINGLE REAGENT stable 30 days at 2-8 °C after reconstitution - Ratio: Sample/Reagent: 1/100 - End-Point reaction in 10 min - Color stable 30 min - Linearity 900 mg/dL.
5x10 mL
Colorimetric
    


17619H
Phosphorus 390 mL (6x65)
Molybdenum blue direct method - Wavelength 650 nm - SINGLE REAGENT stable 60 days at 2-8 °C after reconstitutions - Ratio: Sample/Reagent: 1/30 - End-Point reaction 3 min - Color stable 60 min - Linearity 10 mg/dL.
6x65 mL
Colorimetric
    

17182
Phosphorus Enzymatic 50 mL (5x10)
Enzymatic colorimetric Trinder method - Wavelength 505 nm - SINGLE REAGENT stable 15 days at 2-8 °C after reconstitution - Ratio: Sample/Reagent: 1/100 - End-Point reaction 5 min - Color stable 30 min - Linearity 16 mg/dL.
5x10 mL
Colorimetric
    


17620H
Total Proteins 390 mL (6x65)
Direct colorimetric Biuret method - Wavelength 546 nm - LIQUID SINGLE REAGENT - Ratio: Sample/Reagent: 1/100 - End-Point reaction 15 min - Color stable 60 min - Linearity 10 g/dL.
6x65 mL
Colorimetric
    

1727501
Urine Proteins 80 mL (4x20)
Direct colorimetric method with Pyrogallol Red at high linearity - Wavelength 600 nm - Without sample blank - SINGLE LIQUID REAGENT - Ratio: Sample/Reagent 1/100 - End-point reaction 1 min - Color stable 30 min - Linearity 210 mg/dL - Sensitivity 1 mg/dL - Standard included in the kit. Recommended controls: (REF 143131 Human Urine Chemistry Ctrl 1 e REF 143231 Human Urine Chemistry Ctrl 2) - Quantimetrix Corporation - CA, USA.
Colorimetric
    


17624H
Triglycerides Liquid 390 mL (6x65)
Enzymatic colorimetric Trinder method (TOOS) - Wavelength 546 nm - SINGLE LIQUID REAGENT - Ratio: Sample/Reagent: 1/100 - End-Point reaction 5 min - Color stable 30 min - Linearity 1000 mg/dL.
6x65 mL
Colorimetric
    


17629H
Urea Liquid 215 mL (3x65+1x20)
Kinetic UV method Urease-GLDH - Wavelength 340 nm - TWO LIQUID REAGENTS - Ratio: Sample/Reagent 1/Reagent 2: 1/100/10 - Fixed time reading - Lag phase 30 sec - Reading 30 sec - Linearity 350 mg/dL - Volumes R1 and R2 are balanced for automated analyzer.
3x65; 1x20 mL
Colorimetric
    


17658H
Uric Acid Liquid 260 mL (4x65)
Enzymatic Trinder method (TOOS) on serum, plasma and urine - Wavelength 546 nm - SINGLE LIQUID REAGENT - Ratio: Sample/Reagent: 1/42 - End-Point reaction 5 min - Color stable 10 min - Linearity 25 mg/dL.
4x65 mL
Colorimetric
    


17640H
Zinc 111 mL (5x20+1x11)
Direct colorimetric method with 5-Br-PAPS - Wavelength 570 nm - Without deproteinization on serum, plasma and seminal fluid - TWO REAGENTS - Ratio: Sample/Reagent 1/Reagent 2: 1/20/2 - End-Point reaction 30 sec. at 37 °C - Color stable 60 min. - Linearity 2000 µg/dL - Standard included in the kit.
5x20; 1x11 mL
Colorimetric
    

17255
Zinc 55 mL (5x10+1x5)
5x10; 1x5 mL
Colorimetric
    


Top