CALIBRATORS
| Ref. |
Product |
Quantity |
No. of Test |
Method |
Docum.
met sds |
Lipoproteins
11202H
Apo-A1/Apo-B/HDL Cal
Lyophilized human based serum - Stable 30 days at -20 °C or 7 days at 2-8 °C after reconstitution - For Kits Apolipoprotein A-1 (REF 11040D), Apolipoprotein B (REF 11042D) and Cholesterol HDL Liquid NG (REF 17201P , REF 17201R).
3x2 mL
Turbidimetry
16203S
HDL/LDL Calibrator
Lyophilized human based serum - Stable 7 days at 2-8 °C after reconstitution or 30 days at -20 °C; Calibration for the kits Cholesterol HDL Liquid NG (REF 17201P, REF 17201R) and Cholesterol LDL Liquid NG (REF 17203D, REF 17203E).
2x1 mL
Colorimetric
Siero multiparametrico plasmaproteine
11200D
Plasmaproteins Cal
Liquid calibrator for plasmaproteins AAT, AGP, A2M, ALB, AT3, C1, CER, C3, C4, HPT, IgA, IgG, IgM, Kappa, Lambda, PAL, TRF determination with sample dilution procedure.
3x1 mL
Turbidimetry
11206D
Plasmaproteins Cal 3x
Liquid concentrated calibrator to be used on the instruments that work without sample dilution procedure for plasmaproteins AAT, AGP, A2M, ALB, AT3, C1, CER, C3, C4, HPT, IgA, IgG, IgM, Kappa, Lambda, PAL, TRF determination.
4x1 mL
Turbidimetry
Specific Test
11524H
Beta-2 Micro Cal Set
Calibrator concentrations: 1.5 - 10 - 50 - 80 mg/dL - To be used with the product REF 11505H for serum, plasma and urine.
1x2 mL
Turbidimetry
11527S
Cystatin C Calibrator
Human based liquid calibrator - Calibrator concentration: from 7 to 9 mg/L - To be used
with REF 11510A - In house standardisation against highly purified material.
1x1 mL
Turbidimetry
11525A
Ferritin Cal Set
Calibrator set concentration: 100-200-500-1000 ng/mL - To be used with the product REF 11509 and REF 11509A.
4x2 mL
Turbidimetry
11521D
CRP Calibrator
Concentration: 5 mg/dL - To be used with the product REF 11502D.
1x5 mL
Turbidimetry
11532
CRP Calibrator Set
Calibrators concentration: 0.5-1.0-2.0-4.0-8.0-16.0-32.0 mg/dL - To be used with the product REF 11508.
7x2 mL
Turbidimetry
11533
CRP Calibrator US
Concentration: 0.25 mg/dL - To be used in combination with CRP Calibrator Set REF 11532 for Ultrasensitive CRP method REF 11508.
1x2 mL
Turbidimetry
11520D
ASO Calibrator
Concentration: 500 UI/mL - To be used with the product REF 11501D.
1x5 mL
Turbidimetry
11526D
Myo Cal Set
Calibrator set concentration: 70/140/280/560 ng/mL - To be used with the product REF 11507D.
4x1 mL
Turbidimetry
11523D
RF Cal Set
Calibrator set concentration: 10/20/40/80/120 IU/mL - To be used with the product REF 11506D.
5x1 mL
Turbidimetry
11207A
Microalbumin Cal Urine (4x1 mL)
Calibrator concentration: about 100 mg/dL - To be used with the product REF 11003D.
4x1 mL
Turbidimetry
11522D
Lp(a) Cal Set
Calibrator set ( 5 levels) approx.range 5-100 mg/dL - To be used with the product REF 11504D.
5x1 mL
Turbidimetry